PCR Processor
|
|
Peltier Based PCR Model
|
|
|
BioEra's Peltier Based PCR Model with its user-friendly program, time and temperature
extending function along with temperature optimization features, makes this system perfect
for affluent performance.
|
|
|
|
Features
|
Specifications
|
|
Cat. No.
|
Cat. No. - BE/CI/PCR/PPCR-01
|
|
Sample Plate Capacity
|
32 X 0.2ml (4 X 8)
|
|
Cooling System
|
Peltier Based
|
|
Sample Plate Temperature Range
|
4.0șC - 100șC with 0.1șC resolution
|
|
data
|
data
|
|
Heat Lid Temperature Range
Maximum Temperature Increase Rate
Maximum Temperature Decrease Rate
|
98șC - 105șC
3șC / sec
2.8șC / sec
|
|
Average Temperature
Increase / Decrease Rate
|
2șC / sec @ 55șC - 95șC
|
|
Maximum Temperature Difference
Between Sample Wells
|
± 0.5șC
|
|
Temperature Control Resolution
|
± 0.1șC
|
|
User Program
|
110
(Each program may contain up to 13 segments
with 3 step cycle for each pogram)
|
|
Additional Features
|
Time Extending Function
Temperature Extending Function
|
|
Power
|
250W
|
|
Dimensions (cm3)
|
28 X 23 X 18
|
|
Weight
|
2.5kg
|
|
|
Features
|
|
|
- Unique, compact and attractive design
- Temperature extending functions
- Time extending functions
- Hot cover for oil-free operation
- Minimum sound during operation
- 110 User friendly program with 13 segment and 3 step cycle for each program
|
|
|
Gradient PCR Model (Peltier Based)
|
|
|
BioEra's Gradient PCR Model is the most convenient model to employ for time saving
in PCR reaction optimization. It is designed to deliver consistent performance and
reliability to suit PCR requirements. Auto-restart, automatic temperature & time
increment / decrement during process, dual capacity of the sample block for 0.2ml
as well as 0.5ml sample volume etc. features make the system perfect to cater academic,
research and professional needs.
|
|
Features
|
|
|
- Unique, compact and attractive design
- Easy-to-learn programming interface for quick and painless programming
- Choice of simulate tube or block temperature control mode
- Sample Block capacity is for 0.2ml as well as 0.5ml sample volume
- Hot cover for oil-free operation
- No Noise during operation
|
|
|
|
Features
|
Specifications
|
|
Cat. No.
|
Cat. No. - BE/CI/PCR/GPCR-02
|
|
Sample Plate Capacity
|
96 wells X 0.2ml & 54 wells X 0.5ml
|
|
Cooling System
|
Peltier Based
|
|
TEMPERATURE
|
|
Temperature Control Range
|
0șC - 100șC
|
|
Maximum Heating Rate
|
3șC / Sec
|
|
Maximum Cooling Rate
|
2-8șC / Sec
|
|
Temperature Uniformity
|
0±.4 șC
|
|
Temperature Accuracy
|
±0 .1șC
|
|
Mode of Temperature Control
|
Simulate Tube & Block
|
|
PROGRAMMING
|
|
Maximum Number of Cycles
|
99
|
|
Time Increment / Decrement
|
1 - 60 Sec
|
|
Temperature Increment / Decrement
|
0.1 - 10șC
|
|
Auto Restart
|
Yes
|
|
Auto Pause
|
Yes
|
|
Ramping Rate
|
0.3șC - 3șC
|
|
Hold at 4șC
|
Forever
|
|
Pause / Stop
|
Yes
|
|
User Programs
|
200
|
|
Screen
|
320 x 240 Pls LCD
|
|
HOT COVER
|
|
Temperature of Hot Cover
|
70șC - 110șC
|
|
Auto Shut Off
|
Yes
|
|
Hot Cover Adjustable
|
Yes
|
|
GRADIENT
|
|
Range of Temperature
|
30șC - 100șC
|
|
Uniformity of Each Column
|
0.3șC
|
|
Accuracy of Each Column
|
0.3șC
|
|
Spread of Gradient
|
2șC - 30șC
|
|
Power
|
50Hz - 60Hz (350W)
|
|
Dimensions (L X W X H)
|
380mm X 270mm X 250mm
|
|
Weight
|
7.2kg
|
|
Communication
|
USB 2.0
|
|